NATIONAL STARCH AND CHEMICAL CORPORATION -- FORMALDEHYDE SOLUTION 37% (15% METHANOL) -- 6850-00N010993
=====================  Product Identification  =====================

Product ID:FORMALDEHYDE SOLUTION 37% (15% METHANOL)
MSDS Date:02/26/1986
FSC:6850
NIIN:00N010993
=== Responsible Party ===
Company Name:NATIONAL STARCH AND CHEMICAL CORPORATION
Address:FINDERNE AVENUE
Box:6500
City:BRIDGEWATER
State:NJ
ZIP:08807
Info Phone Num:201-685-5000
Emergency Phone Num:201-685-5000
CAGE:85091
=== Contractor Identification ===
Company Name:NATIONAL STARCH AND CHEMICAL CORP
Address:10 FINDERNE AVE
Box:6500
City:BRIDGEWATER
State:NJ
ZIP:08807
Country:US
Phone:908-685-5379; FAX:908685-5306
CAGE:85091

=============  Composition/Information on Ingredients  =============

Ingred Name:FORMIC ACID  (SARA III)
CAS:64-18-6
RTECS #:LQ4900000
Other REC Limits:N/K 
OSHA PEL:5 PPM
ACGIH TLV:5 PPM/10 STEL; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:METHYL ALCOHOL (METHANOL)  (SARA III)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: 15.0%
Other REC Limits:N/K 
OSHA PEL:S,200PPM/250STEL
ACGIH TLV:S,200PPM/250STEL; 93
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 48.0%
Other REC Limits:N/K 
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MATL TO AVOID:CHLORIDE,MG,NI,CHLOROFORM & SODIUM
    HYDROXIDE,BERYLLIUM HYDRIDE,BROMINE,CHROMIC ANHYDRIDE,STRONG
    OXIDIZERS.
RTECS #:9999999ZZ
Other REC Limits:N/K 
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:EXPLAN OF CARC:CARC (OSHA,1985).ACGIH A2=SUSP HUM CARC
    (1989).LD50-LC50 MIX:800 MG/KG;(METHANOL) 5628 MG/KG.
RTECS #:9999999ZZ
Other REC Limits:N/K 
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:FORMALDEHYDE  (SARA III)
CAS:50-00-0
RTECS #:LP8925000
Fraction by Wt: 37.0%
Other REC Limits:N/K 
OSHA PEL:SEE 1910.1048
ACGIH TLV:C 0.3 PPM; A2; 9293
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 RAT ORAL (FORMALDEHYDE) (SEE ING 6)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:FORMALDEHYDE:OCULAR DAMAGE,VISION
    LOSS,DERMATITIS,LIVER/KIDNEY DAMAGE,SECONDARY
    STERILIZATION,DEATH,LACRIMATION,PULMONARY
    EDEMA,PNEUMONITIS.METHANOL:BLINDNESS W/ OPTIC
    NEURITIS,DERMATITIS,SKIN ABSORPT ION,LIVER/KIDNEY
    DAMAGE,CEREBRAL/PULMONARY EDEMA,DEATH.FORMIC ACID IS CORROSIVE.
Explanation of Carcinogenicity:FORMALDEHYDE:LIM EVID FOR CARC IN
    HUM/SUFF IN ANIM (IARC,1987).SUSP HUM/KNOWN ANIM CARC
    (NTP,1985).KNOWN HUM (SEE ING 6)
Effects of
    Overexposure:FORMALDEHYDE:EYES:CORR,IRRIT,BLINDNESS.SKIN:CORR,SENSI
    T,NARCTC,TOX,BURNS.INGEST:NARCTC,NAUS,VOMIT,PAIN,UNCON,CONVL.INHAL:
    CORR,NARCTC,TOX,IRRIT,BRTHG
    DFCLTY,LACRIMATION.METHANOL:EYES:LESIONS,CONJ.SKIN:
    ECZEMA,DERMAT,ABSORBED-NARCOSIS,VISUAL
    IMPAIRMENT.INGEST/INHAL:BLINDNESS W/ OPTIC
    NEURITIS,NARCOSIS,INCOOR,PAIN,NAUS.
Medical Cond Aggravated by Exposure:N/K 

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES .SKIN:N/K .INGESTION:CALL MD IMMEDIATELY .INHALATION:REMOVE
    TO FRESH AIR.SUPPORT BREATHING (GIVE O*2/ARTIFICIAL RE SPIRATION)
    .ANTIDOTE:NO SPECIFIC ANTIDOTE.TREAT SYMPTOMATICALLY AND
    SUPPORTIVELY.

=====================  Fire Fighting Measures  =====================

Flash Point Method:CC
Flash Point:122F,50C
Lower Limits:73%
Upper Limits:7%
Extinguishing Media:DRY CHEM,CO*2,H*2O SPRAY,FOAM.LRG
    FIRE-SPRAY,FOG,ALCOHOL FOAM.EXTING ONLY IF FLOW STOPS;FLOOD W/ H*2O
    FOG;STREAM INEFT.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA,FULL PROT EQUIP
    .REMOVE CONTR IF POSS/COOL W/ H*2O FROM SIDE UNTIL WELL AFTER FIRE
    OUT.FOR MASSIVE FIRE USE UNMANNED (SUP DAT)
Unusual Fire/Explosion Hazard:MOD FIRE/EXPLO HAZ NEAR HEAT/FLAME.VAP
    HEAVY (>AIR),TRAVEL LONG DIST,IGNITE & FLASH BACK.VAP-AIR MIX EXPLO
    ABOVE FL PT.FORMALDEHYDE+OTHERS YIELDS EXPLO CMPDS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SHUT OFF IGNIT SOURCES.DO NOT TOUCH.STOP
    LEAK.REDUCE VAP W/ WATER SPRAY.DO NOT GET WATER IN CONTR.TAKE UP W/
    SAND,OTHER;PLACE IN CONTR.LARGER-DIKE AHEAD OF SPILL.NO
    SMKNG,FLAMES,FLARES.KEEP PEOPLE AWA Y.ISOLATE AREA/DENY ENTRY.
Neutralizing Agent:N/K 

======================	Handling and Storage  ======================

Handling and Storage Precautions:N/K 
Other Precautions:N/K 

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
    CONCENTRATION BELOW TLV .
Protective Gloves:APPROPRIATE PROTECTIVE GLOVES.
Eye Protection:CHEM WORK GOGG  & FACESHIELD.
Other Protective Equipment:IMPERVIOUS CLOTHING & EQUIPMENT;EYEWASH
    FOUNTAIN.
Work Hygienic Practices:N/K 
Supplemental Safety and Health
SOLV SOL:SOL IN ALCOHOLS,ACETONE.ODOR THRESHOLD:1 PPM.FIRE FIGHT
    PROC:HOSE HOLDER/MONITOR NOZZLES OR LEAVE,LET BURN.LEAVE IMMED IF
    RISING SOUND FROM VENT/TANK DISCOLORATION.APPLY WATER FROM FAR
    DIST,A VOID VAP,KEEP UPWIND.MATL TO AVOID:STRONG OXIDIZERS.TOX
    RXN-HCL.METHANOL:EXPLO RXN-CALCIUM CARBIDE,CYANURIC (SEE ING 5)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:205F,96C
Melt/Freeze Pt:M.P/F.P Text:5F,-15C
Decomp Temp:Decomp Text:N/K 
Vapor Pres:N/K 
Vapor Density:1.04,AIR=1
Spec Gravity:1.08 (WATER=1)
pH:2.8-4
Solubility in Water:MISCIBLE
Appearance and Odor:COLORLESS LIQUID WITH A PUNGENT ODOR.

=================  Stability and Reactivity Data  =================

FORMALDEHYDE:EXPLO RXN-NITROMETHANE,PEROXYFORMIC/PERCHLORIC ACID,MG
    CARBONATE,NO*2,HYDROGEN PEROXIDE,ANILINE,(SEE SUPP)
Stability Condition to Avoid:COLD,AIR SENSITIVE.IGNITE BY
    HEAT,SPK,FLAME;CONTR EXPLODE IN FIRE.VAP EXPLO HAZ IN/OUTSIDE,IN
    SEWER (FIRE/EXPLO HAZ).
Hazardous Decomposition Products:OXYGEN FROM AIR CAN OXIDIZE
    FORMALDEHYDE TO FORMIC ACID,ESP WHEN HEATED.FORMIC ACID IS
    CORROSIVE.
Conditions to Avoid Polymerization:FORMALDEHYDE TO PARAFORMALDEHYDE
    (NON-HAZ).WILL POLYMERIZE W/ ACTIVE ORGANIC MATL (PHENOL) W/ SUDDEN
    PRESS DEVELOPMENT.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
    FEDERAL,STATE AND LOCAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.