SCHULLER INTERNATIONAL INC -- FIBER GLASS INSULATION, MICROLITE -- 5970-00N059083
=====================  Product Identification  =====================

Product ID:FIBER GLASS INSULATION, MICROLITE
MSDS Date:01/01/1993
FSC:5970
NIIN:00N059083
=== Responsible Party ===
Company Name:SCHULLER INTERNATIONAL INC
Box:5108
City:DENVER
State:CO
ZIP:80127-5108
Country:US
Info Phone Num:303-978-4900
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:SCHUL
=== Contractor Identification ===
Company Name:SCHULLER INTERNATIONAL INC.
Box:5108
City:DENVER
State:CO
ZIP:80217-5108
Country:US
Phone:303-978-4900
CAGE:75165
Company Name:SCHULLER INTERNATIONAL, INC.
Address:717 SEVENTEENTH STREET
Box:5108
City:DENVER
State:CO
ZIP:80217-5108
Country:US
Phone:303-978-2000
CAGE:SCHUL

=============  Composition/Information on Ingredients  =============

Ingred Name:FIBERGLASS; (FIBROUS GLASS)
CAS:65997-17-3
Fraction by Wt: 85-98%
OSHA PEL:5 MG/M3 RESP DUST
ACGIH TLV:10 MG/M3 (<7MICRONS)

Ingred Name:UREA EXTENDED PHENOL-FORMALDEHYDE RESIN CURED
CAS:25104-55-6
Fraction by Wt: 2-15%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:KRAFT, FOIL/KRAFT, PSK, FSK, AND VARIOUS METAL BUILDING
    FACINGS
Fraction by Wt: <1%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:FIRST AID PROC: MAY CAUSE LENS OF EYE TO BE SCRATCHED.
    FLUSH EYES W/LGE AMTS OF WATER FOR AT LEAST 15 MIN. IF (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4: IRRIT PERSISTS, CONT MD. NOTES TO MD: DUSTS FROM
    PROD ARE MECH IRRIT & ARE NOT EXPECTED TO PRODUCE ANY (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5: CHRONIC HLTH EFTS. TREATMENT SHOULD BE DIRECTED
    TOWARD REMOVING SOURCE OF IRRIT W/SYMPTOMATIC TREATMENT AS NEC.
RTECS #:9999999ZZ

Ingred Name:RESP PROT: RESP PROT. FOR EXPOS EXCEEDING 10 FIBERS PER
    CUBIC CENTIMETER (F/CC), A NIOSH/MSHA APPRVD, HALF-MASK (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7: RESP W/HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTER
    CARTRIDGE SHOULD BE USED (E.G., MSA COMFO II W/"H" (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8: CARTRIDGES, & SURVIVAIR HALF-MASK W/#1090-00
    CARTRIDGES). RESP SHOULD BE USED IF VENT UNAVAIL/INADEQ FOR (ING
    10)
RTECS #:9999999ZZ

Ingred Name:ING 9: KEEPING DUST AND FIBER LEVELS BELOW THE APPLICABLE
    EXPOSURE LIMITS.
RTECS #:9999999ZZ

Ingred Name:VENT: SHOULD BE PROVIDED AS NEC TO KEEP AIRBORNE DUST &
    FIBERS < APPLIC EXPOS LIM & GUIDELINES. NEED FOR VENT (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11: SYS SHOULD BE EVALUATED BY PROFESSIONAL INDUSTRIAL
    HYGIENIST, WHILE DESIGN OF SPECIFIC VENT SYS SHOULD (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: BE CONDUCTED BY A PROFESSIONAL ENGINEER.
RTECS #:9999999ZZ

Ingred Name:HYGIENE PRACT: WASHED SEPARATELY FROM OTHER CLOTHES &
    WASHER SHOULD BE RINSED THORO (RUN EMPTY FOR COMPLETE (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14: WASH CYCLE). THIS WILL REDUCE THE CHANCES OF FIBER
    GLASS BEING TRANSFERRED TO OTHER CLOTHING.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: DUST MAY CAUSE
    IRRIT/SCRATCHINESS OF THROAT, &/ITCHING IN EYES & SKIN. CHRONIC:
    ANIMALS INJECTED W/FIBER GLASS IN LUNGS/CHEST CAVITY DEVELOPED
    TUMORS. STUDIES OF FIBER GLASS WORKERS HAVE SHOWN  A SML EXCESS OF
    LUNG CANCER WHEN COMPARED TO LOC CTL GROUPS. HOWEVER, THERE IS NO
    EVIDENCE THAT THIS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: EXCESS IS RELATED TO BRTHG FIBER
    GLASS. TARGET ORGANS: LUNGS, THROAT, SKIN & EYES. SYMP OF OVEREXP:
    INHAL: IRRIT OF UPPER RESP TRACT (SCRATCHY THROAT), COUGHING, &
    CONGESTION MAY OCCUR IN EX TREME EXPOS. SKIN: TEMPORARY IRRIT
    (ITCHING)/REDNESS MAY OCCUR. INGEST: MAY CAUSE TEMPORARY IRRIT TO
    GI TRACT (SUP DAT)
Medical Cond Aggravated by Exposure:PREEXISTING CHRONIC EYE, SKIN OR
    RESPIRATORY DISEASES.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT &
    BLOW NOSE TO REMOVE FIBERS. SKIN: WASH GENTLY W/SOAP & WARM WATER
    TO REMOVE DUST & FIBERS. WASH HANDS BEFORE EATING/USING RESTROOM.
    INGEST: IR RIT OF GI TRACT MAY OCCUR & SHOULD BE TREATED
    SYMPTOMATICALLY. RINSE MOUTH W/WATER TO REMOVE FIBERS, & DRINK
    PLENTY OF WATER TO HELP REDUCE IRRIT. EYES: DO NOT RUB/SCRATCH
    EYES. DUST PARTICLES (ING 4)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PICK UP LARGE PIECES. VACUUM DUSTS. IF
    SWEEPING IS NECESSARY, USE A DUST SUPPRESSANT (SUCH AS WATER). DO
    NOT DRY SWEEP DUST ACCUMULATION. THESE PROCEDURES WILL HELP TO
    MINIMIZE POTENTIAL EXPOSURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE PROTECTIVE EQUIPMENT WHEN HANDLING
    LOOSE OR UNPACKAGED MATERIAL. MATERIAL SHOULD BE KEPT DRY, AND
    PROTECTED FROM THE ELEMENTS.
Other Precautions:WAREHOUSE STORAGE SHOULD BE IN ACCORDANCE WITH
    PACKAGE DIRECTIONS, IF ANY.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE A NIOSH/MSHA APPRVD DUST/MIST RESP TO
    PROTECT AGAINST NUISANCE DUST & FIBERS (E.G. 3M 9900 & MOLDEX
    2200). OPERATIONS SUCH AS WELDING, BLOWING, TEAR OUT, & SPRAYING
    MAY GENERATE AIRBORNE FIBER CON CS REQUIRING HIGHER LEVEL OF (ING
    7)
Ventilation:LOC EXHAUST VENT SHOULD BE PROVIDED AT AREAS OF CUTTING TO
    REMOVE AIRBORNE DUST & FIBERS. GEN DILUTION VENT (ING 11)
Protective Gloves:LEATHER/COTTON GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:USE BARRIER CREAMS TO REDUCE SKIN CONT &
    IRRIT. WEAR LOOSE FITTING, LONG SLEEVED CLTHG TO PROT SKIN FROM
    IRRIT.
Work Hygienic Practices:EXPOSED SKIN AREAS SHOULD BE WASHED W/SOAP &
    WARM WATER AFTER HNDLG/WORKING W/FIBER GLASS. CLTHG SHOULD BE (ING
    14)
Supplemental Safety and Health
APPEAR/ODOR: OR LOOSE FILL INSULATION, NO SIGNIFICANT ODOR. HAZ DECOMP
    PROD: DERIVED FROM PYROLYSIS/BURNING OF RESIN. DECOMP PROD MAY
    INCLUDE CO*2, CO, CARBON PARTICLES, FORMALDEHYDES, & TRACES OF HYD
    ROGEN CYANIDE. EFTS OF OVEREXP: (ESPECIALLY STOMACH). EYES:
    TEMPORARY IRRIT (ITCHING)/REDNESS MAY OCCUR.

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:>1300F,>704
Spec Gravity:VARIABLE
Solubility in Water:NIL
Appearance and Odor:GOLD TO YELLOW FIBROUS GLASS BOARD/BLANKET W/W/OUT
    KRAFT/OTHER FACINGS (SUP DAT
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DECOMP PROD FROM MATL ARE THOSE THAT
    WOULD BE EXPECTED FROM ANY ORG (CARBON CONTAINING) MATL, & ARE
    MAINLY (SUP DAT)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
    FEDERAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their